A Real Beast of a Machine - Gorilla Power

Gorilla Power GP5500DF — 5500W Dual-Fuel Generator (Petrol / Propane)

Reliable, flexible, ready. Run on petrol or propane with 5500W max / 5000W running, large 25 L tank, and electric / recoil / wireless remote start. Built tough for home backup, sites and events.

🔎 Where This Model Sits in the Gorilla Power Range

From ultra-portable inverters to big dual-fuel & diesel sets — this GP5500DF is a mid-high output dual-fuel unit with capacity to run multiple items at once.

2.0kW Inverter — GP2000i 3.5kW Inverter — GP3500i 3.8kW Inverter ES — GP3800iE 5.0kW Inverter — GP5000iE 5.5kW Dual-Fuel — GP5500DF 6.5kW Dual-Fuel — GP6500DF 8.0kW Petrol — GP8000iE 8.3kW Dual-Fuel — GP8300DF 12.8kW Diesel — GP12800D

2.0kW3.53.85.05.56.58.08.312.8kW

💡 Key Features

  • 5500W max / 5000W running — run more devices simultaneously (sum of running ≤ 5.0 kW).
  • Dual-Fuel system — switch between petrol and propane for flexibility and availability.
  • Electric, recoil & wireless remote start — control it your way.
  • Large 25 L tank — extended runtime for outages and long shifts.
  • Low-oil shut-off — engine protection built-in.
  • Site-ready outputs — 230V/32A + twin 110V/32A + 12V DC.

CampingHome EssentialsToolsHigh-Demand

More running watts = more items at once; keep headroom for motor start surges.

🔌 Sockets & Inputs — Front Panel at a Glance

230V 32A (CEE)
High-power feed to a board or single large load.
2 × 110V 32A (CEE)
Site-safe sockets for tools & leads.
12V DC Output
Battery charging / DC accessories.
Ground (earth) terminal
Added safety & compliance.

⚡ Running vs. Starting Watts — Know the Difference

Running watts = power to keep equipment operating.
Starting watts = brief surge to start motors/compressors.
Running watts (blue bar)
Starting watts (red marker)
Generator running capacity (dotted line)
GP5500DF: 5500W max / 5000W running
Fridge-Freezer



05500W
Run ≈ 150–250W | Start ≈ 800–1200W
Microwave



05500W
Run ≈ 900–1200W | Start ≈ Same
Table Saw (10")



05500W
Run ≈ 1500–1800W | Start ≈ 2500–3000W
Air Compressor (2 HP)



05500W
Run ≈ 1400–1600W | Start ≈ 3500–4500W
Pressure Washer (2 kW, induction)



05500W
Run ≈ 1800–2000W | Start ≈ 3000–3500W

Typical values — always check your device label. Add up running watts for items used together, and keep the single largest start surge within your headroom (≈5.0 kW on this model).

📐 What Size Generator Do I Need?

Item Typical Running Typical Starting GP5500DF?
Laptop + Phone Charging 100–200W ≈ Same ✅ Easy (many)
LED TV + Router + Lights 150–300W ≈ Same ✅ Easy (many)
Fridge-Freezer 120–200W 800–1200W ✅ Yes (multiple)
String / Hedge Trimmer 300–450W 700–1200W ✅ Yes (multiple)
Drill / Hand Sander 500–600W 800–1200W ✅ Yes (multiple)
Paint Sprayer 500–600W ≈ 600W ✅ Yes
Work Light (LED/Halogen) 300–1000W ≈ Same ✅ Multiple OK
Microwave 800–1200W ≈ Same ✅ Yes (with other light loads)
Pressure Washer (electric) 1800–2000W 3000–3500W ✅ Yes
Table Saw (10") 1500–1800W 2500–3000W ✅ Yes
Space Heater / Kettle 1500–3000W ≈ Same ✅ Yes (watch totals)
Air Compressor (2 HP) 1400–1600W 3500–4500W ✅ Usually OK
Electric Oven (single) 3000–3600W ≈ Same ✅ Yes (solo or light extras)

Guide only — add up running watts for items used together, then ensure the single highest starting surge stays within generator limits.

🧭 Why Dual-Fuel Matters

  • Fuel flexibility — choose petrol for convenience or propane for long-term storage.
  • Lower emissions on propane — cleaner burn, less carbon build-up.
  • Extended runtime — switch fuels mid-use to keep working.
  • Cost control — pick the most economical fuel for the job.

📊 Technical Specifications

Maximum Watts 5500W
Running Watts 5000W
Fuel Type Petrol / Propane (LPG)
Fuel Tank 25 L
Oil Capacity 1.1 L
Weight 91 kg
Starting System Recoil / Electric / Wireless Remote
Frequency 50 Hz

Instruction Manual (PDF)

🧠 Tips for Choosing the Right Generator

  • Total your running watts for everything you’ll use together.
  • Identify the largest starting surge (motors/compressors) and leave headroom.
  • Use correct sockets — 110V (yellow) for UK sites; 230V/32A for boards/large loads.
  • Plan runtime — tank size + LPG bottle = hours between stops.
Versatile dual-fuel power with site-ready sockets — Order your Gorilla Power GP5500DF today.
Equip2clean
Petrol Generator
A Real Beast of a Machine - Gorilla Power

Gorilla Power GP5500DF — 5500W Dual-Fuel Generator (Petrol / Propane)

Reliable, flexible, ready. Run on petrol or propane with 5500W max / 5000W running, large 25 L tank, and electric / recoil / wireless remote start. Built tough for home backup, sites and events.

🔎 Where This Model Sits in the Gorilla Power Range

From ultra-portable inverters to big dual-fuel & diesel sets — this GP5500DF is a mid-high output dual-fuel unit with capacity to run multiple items at once.

2.0kW Inverter — GP2000i 3.5kW Inverter — GP3500i 3.8kW Inverter ES — GP3800iE 5.0kW Inverter — GP5000iE 5.5kW Dual-Fuel — GP5500DF 6.5kW Dual-Fuel — GP6500DF 8.0kW Petrol — GP8000iE 8.3kW Dual-Fuel — GP8300DF 12.8kW Diesel — GP12800D

2.0kW3.53.85.05.56.58.08.312.8kW

💡 Key Features

  • 5500W max / 5000W running — run more devices simultaneously (sum of running ≤ 5.0 kW).
  • Dual-Fuel system — switch between petrol and propane for flexibility and availability.
  • Electric, recoil & wireless remote start — control it your way.
  • Large 25 L tank — extended runtime for outages and long shifts.
  • Low-oil shut-off — engine protection built-in.
  • Site-ready outputs — 230V/32A + twin 110V/32A + 12V DC.

CampingHome EssentialsToolsHigh-Demand

More running watts = more items at once; keep headroom for motor start surges.

🔌 Sockets & Inputs — Front Panel at a Glance

230V 32A (CEE)
High-power feed to a board or single large load.
2 × 110V 32A (CEE)
Site-safe sockets for tools & leads.
12V DC Output
Battery charging / DC accessories.
Ground (earth) terminal
Added safety & compliance.

⚡ Running vs. Starting Watts — Know the Difference

Running watts = power to keep equipment operating.
Starting watts = brief surge to start motors/compressors.
Running watts (blue bar)
Starting watts (red marker)
Generator running capacity (dotted line)
GP5500DF: 5500W max / 5000W running
Fridge-Freezer



05500W
Run ≈ 150–250W | Start ≈ 800–1200W
Microwave



05500W
Run ≈ 900–1200W | Start ≈ Same
Table Saw (10")



05500W
Run ≈ 1500–1800W | Start ≈ 2500–3000W
Air Compressor (2 HP)



05500W
Run ≈ 1400–1600W | Start ≈ 3500–4500W
Pressure Washer (2 kW, induction)



05500W
Run ≈ 1800–2000W | Start ≈ 3000–3500W

Typical values — always check your device label. Add up running watts for items used together, and keep the single largest start surge within your headroom (≈5.0 kW on this model).

📐 What Size Generator Do I Need?

Item Typical Running Typical Starting GP5500DF?
Laptop + Phone Charging 100–200W ≈ Same ✅ Easy (many)
LED TV + Router + Lights 150–300W ≈ Same ✅ Easy (many)
Fridge-Freezer 120–200W 800–1200W ✅ Yes (multiple)
String / Hedge Trimmer 300–450W 700–1200W ✅ Yes (multiple)
Drill / Hand Sander 500–600W 800–1200W ✅ Yes (multiple)
Paint Sprayer 500–600W ≈ 600W ✅ Yes
Work Light (LED/Halogen) 300–1000W ≈ Same ✅ Multiple OK
Microwave 800–1200W ≈ Same ✅ Yes (with other light loads)
Pressure Washer (electric) 1800–2000W 3000–3500W ✅ Yes
Table Saw (10") 1500–1800W 2500–3000W ✅ Yes
Space Heater / Kettle 1500–3000W ≈ Same ✅ Yes (watch totals)
Air Compressor (2 HP) 1400–1600W 3500–4500W ✅ Usually OK
Electric Oven (single) 3000–3600W ≈ Same ✅ Yes (solo or light extras)

Guide only — add up running watts for items used together, then ensure the single highest starting surge stays within generator limits.

🧭 Why Dual-Fuel Matters

  • Fuel flexibility — choose petrol for convenience or propane for long-term storage.
  • Lower emissions on propane — cleaner burn, less carbon build-up.
  • Extended runtime — switch fuels mid-use to keep working.
  • Cost control — pick the most economical fuel for the job.

📊 Technical Specifications

Maximum Watts 5500W
Running Watts 5000W
Fuel Type Petrol / Propane (LPG)
Fuel Tank 25 L
Oil Capacity 1.1 L
Weight 91 kg
Starting System Recoil / Electric / Wireless Remote
Frequency 50 Hz

Instruction Manual (PDF)

🧠 Tips for Choosing the Right Generator

  • Total your running watts for everything you’ll use together.
  • Identify the largest starting surge (motors/compressors) and leave headroom.
  • Use correct sockets — 110V (yellow) for UK sites; 230V/32A for boards/large loads.
  • Plan runtime — tank size + LPG bottle = hours between stops.
Versatile dual-fuel power with site-ready sockets — Order your Gorilla Power GP5500DF today.
Equip2clean
Petrol Generator
Ex VAT Inc VAT
Log in
CALL US ON
01625 322269
Basket
Call us on 01625 322269
£795.00

Gorilla Power 5500W Dual-Fuel Generator with Electric Start - GP5500E-DF – Reliable & Fuel Efficient


We're here to help Monday to Friday 8:00 - 5:00

Live Chat or call us on 01625 322269

Delivery

Delivery charges will vary depending on your location.

To find out delivery cost to your postcode, add the products your require to your basket and then review your basket, entering the delivery postcode

We look to dispatch all products same-day where possible, we use a close network of couriers we have worked alongside for a number of years and will share any and all shipping updates with you directly.

A Real Beast of a Machine - Gorilla Power

Gorilla Power GP5500DF — 5500W Dual-Fuel Generator (Petrol / Propane)

Reliable, flexible, ready. Run on petrol or propane with 5500W max / 5000W running, large 25 L tank, and electric / recoil / wireless remote start. Built tough for home backup, sites and events.

🔎 Where This Model Sits in the Gorilla Power Range

From ultra-portable inverters to big dual-fuel & diesel sets — this GP5500DF is a mid-high output dual-fuel unit with capacity to run multiple items at once.

2.0kW Inverter — GP2000i 3.5kW Inverter — GP3500i 3.8kW Inverter ES — GP3800iE 5.0kW Inverter — GP5000iE 5.5kW Dual-Fuel — GP5500DF 6.5kW Dual-Fuel — GP6500DF 8.0kW Petrol — GP8000iE 8.3kW Dual-Fuel — GP8300DF 12.8kW Diesel — GP12800D

2.0kW3.53.85.05.56.58.08.312.8kW

💡 Key Features

  • 5500W max / 5000W running — run more devices simultaneously (sum of running ≤ 5.0 kW).
  • Dual-Fuel system — switch between petrol and propane for flexibility and availability.
  • Electric, recoil & wireless remote start — control it your way.
  • Large 25 L tank — extended runtime for outages and long shifts.
  • Low-oil shut-off — engine protection built-in.
  • Site-ready outputs — 230V/32A + twin 110V/32A + 12V DC.

CampingHome EssentialsToolsHigh-Demand

More running watts = more items at once; keep headroom for motor start surges.

🔌 Sockets & Inputs — Front Panel at a Glance

230V 32A (CEE)
High-power feed to a board or single large load.
2 × 110V 32A (CEE)
Site-safe sockets for tools & leads.
12V DC Output
Battery charging / DC accessories.
Ground (earth) terminal
Added safety & compliance.

⚡ Running vs. Starting Watts — Know the Difference

Running watts = power to keep equipment operating.
Starting watts = brief surge to start motors/compressors.
Running watts (blue bar)
Starting watts (red marker)
Generator running capacity (dotted line)
GP5500DF: 5500W max / 5000W running
Fridge-Freezer



05500W
Run ≈ 150–250W | Start ≈ 800–1200W
Microwave



05500W
Run ≈ 900–1200W | Start ≈ Same
Table Saw (10")



05500W
Run ≈ 1500–1800W | Start ≈ 2500–3000W
Air Compressor (2 HP)



05500W
Run ≈ 1400–1600W | Start ≈ 3500–4500W
Pressure Washer (2 kW, induction)



05500W
Run ≈ 1800–2000W | Start ≈ 3000–3500W

Typical values — always check your device label. Add up running watts for items used together, and keep the single largest start surge within your headroom (≈5.0 kW on this model).

📐 What Size Generator Do I Need?

Item Typical Running Typical Starting GP5500DF?
Laptop + Phone Charging 100–200W ≈ Same ✅ Easy (many)
LED TV + Router + Lights 150–300W ≈ Same ✅ Easy (many)
Fridge-Freezer 120–200W 800–1200W ✅ Yes (multiple)
String / Hedge Trimmer 300–450W 700–1200W ✅ Yes (multiple)
Drill / Hand Sander 500–600W 800–1200W ✅ Yes (multiple)
Paint Sprayer 500–600W ≈ 600W ✅ Yes
Work Light (LED/Halogen) 300–1000W ≈ Same ✅ Multiple OK
Microwave 800–1200W ≈ Same ✅ Yes (with other light loads)
Pressure Washer (electric) 1800–2000W 3000–3500W ✅ Yes
Table Saw (10") 1500–1800W 2500–3000W ✅ Yes
Space Heater / Kettle 1500–3000W ≈ Same ✅ Yes (watch totals)
Air Compressor (2 HP) 1400–1600W 3500–4500W ✅ Usually OK
Electric Oven (single) 3000–3600W ≈ Same ✅ Yes (solo or light extras)

Guide only — add up running watts for items used together, then ensure the single highest starting surge stays within generator limits.

🧭 Why Dual-Fuel Matters

  • Fuel flexibility — choose petrol for convenience or propane for long-term storage.
  • Lower emissions on propane — cleaner burn, less carbon build-up.
  • Extended runtime — switch fuels mid-use to keep working.
  • Cost control — pick the most economical fuel for the job.

📊 Technical Specifications

Maximum Watts 5500W
Running Watts 5000W
Fuel Type Petrol / Propane (LPG)
Fuel Tank 25 L
Oil Capacity 1.1 L
Weight 91 kg
Starting System Recoil / Electric / Wireless Remote
Frequency 50 Hz

Instruction Manual (PDF)

🧠 Tips for Choosing the Right Generator

  • Total your running watts for everything you’ll use together.
  • Identify the largest starting surge (motors/compressors) and leave headroom.
  • Use correct sockets — 110V (yellow) for UK sites; 230V/32A for boards/large loads.
  • Plan runtime — tank size + LPG bottle = hours between stops.
Versatile dual-fuel power with site-ready sockets — Order your Gorilla Power GP5500DF today.

Payment & Security

Payment methods

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Have a question?

If you have any questions about our products or would like to learn more about our shipping options please feel free to contact one of our team today.